ANATEL PAT700 TOC Analyzer

Reliable TOC Monitoring for Pharmaceutical Water Systems

The ANATEL PAT700 Total Organic Carbon (TOC) Analyzer is engineered to support pharmaceutical manufacturing by ensuring accurate, compliant water quality testing. Ideal for Purified Water (PW) and Water for Injection (WFI) systems, and for Clean-In-Place processes, the PAT700 helps meet critical pharmacopeial standards including USP<643>, USP<645>, and EP 2.2.44

Key Features

  • 3-in-1 Measurement Measures TOC, Uncompensated Conductivity, and Temperature from a single analyzer.
  • Pharmacopeial Compliance Can be fully validated to meet USP <643> and EP2.2.44 requirements for TOC, and USP <645> for Conductivity.
  • Extended Service Intervals Requires calibration and servicing only once every 12 months.
  • Automated Sample Capture Automatically collects a water sample when a TOC excursion is detected for root-cause analysis.
  • Pre-Loaded SOPs with Visual Guidance Includes intuitive, step-by-step Standard Operating Procedures (SOPs) with on-screen pictures and prompts.

Benefits

  • Ensure Regulatory Compliance Maintain confidence in meeting global pharmacopeial requirements with validated performance.
  • Simplify Operations and Training Built-in SOPs reduce operator errors and accelerate onboarding of new users.
  • Minimize Downtime and Maintenance Costs Long calibration and service intervals lower the total cost of ownership.
  • Rapid Troubleshooting Immediate sample capture helps diagnose and resolve TOC anomalies quickly and effectively.
  • Compact, Integrated Solution Combines multiple measurements in one unit, saving space and simplifying system integration.


Explore the Full Potential of the ANATEL PAT700 TOC Analyzer:

Explore ANATEL PAT700 Models

Running the ANATEL PAT700

 

Content and Resources

Filter by:
Resource Type
Importance of TOC measurement in WFI in light of European Pharmacopoeia change This paper discusses the increased focus on Total Organic Carbon (TOC) and conductivity measurement, especially for companies seeking to use RO water treatment plants to create WFI, and provides best-practice advice for calibration.
European Pharmacopoeia EP 2.2.44 and Total Organic Carbon This paper discusses the background behind the European Pharmacopoeia&rsquo;s focus on complete oxidation of TOC in the light of the increased importance of on-line Total Organic Carbon (TOC) and conductivity measurement.
21 CFR Part 11 Data Integrity for On-line WFI Instruments This application note takes a look at how quality-critical on-line Total Organic Carbon (TOC) and conductivity instrumentation for WFI (water for injection) quality control can be configured to help companies comply with the FDA&rsquo;s expectations on data integrity, including the use of Microsoft Active Directory and PDF data export.
Validation of On-line Total Organic Carbon Analysers for Release Testing Using ICH Q2 This paper discusses how characteristics for consideration during the validation of analytical procedures may be applied to on-line Total Organic Carbon (TOC) analysers to enable them to be used to provide release test data for Water for Injection (WFI) and Purified Water (PW).
Automating Biopharma Quality Control to Reduce Costs and Improve Data Integrity This paper takes a look at four common quality control procedures and how automation can help improve data integrity by reducing opportunities for human error, whilst also saving time and reducing operating costs.